Back To Index  <<  Back To Templates

active Template  XD-LAB Author

Id 1.3.6.1.4.1.19376.1.3.10.2.2
ref
XDLAB-
Effective Date 2016‑07‑05
Status active Active Version Label 2017
Name IHEHeaderAuthor Display Name XD-LAB Author
Description
en-US

At least one ClinicalDocument/author SHALL be present with a time in accordance with the HL7 CDA R2 standard and further constrained by this specification to require the presence of name, addr and telecom. The author/time element carries the date&time the laboratory report was produced. The laboratory report can be authored by a software system or by a person or by both.

Classification CDA Header Level Template
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 1 template, Uses 3 templates
Used by as Name Version
2.16.840.1.113883.2.9.10.1.1 Include draft Referto di Medicina di Laboratorio (LAB) 2018‑04‑16
Uses as Name Version
1.3.6.1.4.1.19376.1.3.10.9.18 Containment active PlayingEntity or person with Name (2017) DYNAMIC
1.3.6.1.4.1.19376.1.3.10.9.19 Containment active Laboratory Device (2017) DYNAMIC
1.3.6.1.4.1.19376.1.3.10.9.13 Containment active Organization with Name, Addr, Telecom (2017) DYNAMIC
Relationship Specialization: template 2.16.840.1.113883.10.12.102 CDA author (2005‑09‑07)
ref
ad1bbr-
Item DT Card Conf Description Label
hl7:author
1 … * R (IHEdotshor)
hl7:time
TS 1 … 1 R en-US

The author/time element carries the date&time the laboratory report was produced.

(IHEdotshor)
hl7:assignedAuthor
1 … 1 R (IHEdotshor)
hl7:addr
AD 1 … * R en-US

All persons (including the patient) and organizations mentioned in the document SHALL provide elements name, addr and telecom.

(IHEdotshor)
hl7:telecom
TEL 1 … * R en-US

All persons (including the patient) and organizations mentioned in the document SHALL provide elements name, addr and telecom.

(IHEdotshor)
Choice 0 … 1 Elements to choose from:
hl7:assignedPerson
en-US

All persons (including the patient) and organizations mentioned in the document SHALL provide elements name, addr and telecom.


Contains 1.3.6.1.4.1.19376.1.3.10.9.18 PlayingEntity or person with Name (DYNAMIC)
(IHEdotshor)
hl7:assignedAuthoringDevice
en-US

ClinicalDocument/author SHALL be present in accordance with the HL7 CDA R2 standard


Contains 1.3.6.1.4.1.19376.1.3.10.9.19 Laboratory Device (DYNAMIC)
(IHEdotshor)
hl7:representedOrganization
0 … 1 en-US

All persons (including the patient) and organizations mentioned in the document SHALL provide elements name, addr and telecom.


Contains 1.3.6.1.4.1.19376.1.3.10.9.13 Organization with Name, Addr, Telecom (DYNAMIC)
(IHEdotshor)